Salla CHC eAir E right
Ventilation unit with heat recovery, electrical after heater and connection for cooker hood. The unit is equipped with Enervent eAir control.
Complementary products
Enervent Salla is best suited for apartments, detached houses and villas. It is a perfect ventilation unit for spaces that many other units can’t fit into. Going short of size does not mean going short of features – Salla is proof that efficiency does not equal size.
Enervent Salla is lower than most ventilation units and it has a built-in water lock for condense water. Due to these features, no installation space is required under the unit. It can i.e. be placed over a washing tower.
The CHC model has a connection for the cooker hood, which means no separate extract duct for the cooker hood is needed.
General information
Air volume flow: 50…360 m³/h EcoDesign classification: A Reference flow rate according to EcoDesign directive (50 Pa): 252 m³/h
Pressure difference: 15 to 125 Pa
Leakage external: < 5% (test pressure 300Pa)
Leakage internal: < 5%
Duct size: Ø 160 mm
Duct size CHC: Ø 125 mm
Weight: 50 kg
Standard filters: ISO ePM1 70 % / ISO Coarse 90 % (F7/M5)
IP class: IP44 (external control IP20)
Condense connection: ¼” internal thread
Nominal voltage: 230 V
Nominal current: Motors 1,8 A total, electrical after heating 1.7 A
Fans
Supply and exhaust air fan type: Ebm-Papst
Supply and exhaust air motor type: G3G146-ED19-10
Nominal voltage: 230 V (AC), EC-type with internal electronics
Type of fan blade: Radial forward
Nominal power: 118 W
Acoustical data: 65 dB(A) DIN 45635-1 ISO 3745
Fan control eAir control: Stepless (supply and exhaust running separately)
Heat recovery
Heat exchanger type: Rotating heat exchanger
Heat exchanger material: Aluminium
Heat exchanger surface: 57 m²
Heat exchanger dimensions: 370 x 200 mm (60 μ)
Heat exchanger motor: 5 W
Ventilation unit annual temperature efficiency (EN 13141-7:2010): 84 %
Supply air annual heat recovery efficiency* (EN 16798-3:2017): 96 %
Extract air annual heat recovery efficiency* (D5:2012): 83 %
* supply air +18°C, extract air +21°C, exhaust air temperature limit -7°C
Other information
Material inside cover: Steel sheet, zinc coated
Material outside cover: Steel sheet, zinc coated, powder painted
Standard electric after heater efficiency: 400 W