LTR-5 Z eAir W-CG

SKU: 10023760
EAN: 6438269032953
Delivery time: 2 weeks, will be confirmed separately

Ventilation unit with heat recovery, after heating with water and duct cooler for cooled water. The unit is equipped with Enervent eAir control.

Available

The Enervent LTR-5 Z is suitable for single-family homes, terraced houses and commercial premises. The LTR series units can be installed on roofs, attics, ceilings or technical rooms. Horizontal installation often saves a lot of space. The LTR series units are well insulated and can be installed in cold places. The ventilation unit requires additional insulation if the ambient temperature drops below -10 ° C.

The simple yet ingenious design of the air handling unit and the low pressure drop ensure low cost, safety and very low noise levels. The LTR-5 Z’s hatch can be used as a hinged or detachable hatch. The swing cover is interchangeable to meet the requirements of the installation site.

General information

Air volume flow @ 100 Pa: 50–700 m³/h
Pressure difference: 25–100 Pa
Leakage external: < 5% (test pressure 300Pa)
Leakage internal: < 5% (test pressure 300Pa)
Duct size: Ø 200 mm
Weight: 68 kg
Standard filters, 2 x bag filter: ISO ePM1 60%/ISO Coarse 80% (F7/M5)
IP class: IP44 (external control IP20)
Condense connection: ¼” internal thread
Nominal voltage: 230 V.
Nominal current: Motors 2.7 A total, electrical after heating 9 A

Fans

Supply and exhaust air fan type: Ebm-Papst
Supply and exhaust air motor type: R3G190-RD45-17
Nominal voltage: 230 V (AC), EC-type with external electronics
Type of fan blade: Radial backward
Nominal power: 169 W, 1.35 A, 50 Hz
Fan control eAir control: Stepless (supply and exhaust running separately)

Heat exchanger

Heat exchanger type: Rotating heat exchanger
Material: Aluminium
Heat exchanger surface: 71 m²
Heat exchanger dimensions: 460 x 241 x 465 (60 μ)
Heat exchanger motor: 5 W
Ventilation unit annual temperature efficiency (EN 13141-7:2010): 84,7 %
Supply air annual heat recovery efficiency* (EN 16798-3:2017): 96,8 %
Extract air annual heat recovery efficiency* (D5:2012): 84 %
* supply air +18°C, extract air +21°C, exhaust air temperature limit -7°C

Other information

Material inside cover: Steel sheet, zinc coated
Material outside cover: Steel sheet, zinc coated
Sound level in supply air duct at fan speeds 20, 40, 60, 80 and 100% LWA:
LPA, dB(A), 10 m²: sound absorption:
Standard electric after heater efficiency: 2 000 W
Positioning of cooling (CG) coil: in duct

Do you need help choosing the right product?

We will gladly help you. Contact our customer service phone +358 9 4255 0305 (week days 8-16 UTC+2), e-mail: enervent@enervent.com or technical support phone +358 9 4255 0303 (week days 8-16 UTC+2), e-mail: service@enervent.com.